Date

New constraints on ultraheavy dark matter from the LZ experiment

The LZ collaboration Aalbers, J. ; Akerib, D.S. ; Al Musalhi, A.K. ; et al.
Phys.Rev.D 109 (2024) 112010, 2024.
Inspire Record 2758452 DOI 10.17182/hepdata.151392

Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV/$c^2$ to a few TeV/$c^2$. Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a re-analysis of the first science run (SR1) of the LZ experiment, with an exposure of $0.9$ tonne$\times$year, to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 10$^{17}$ GeV/$c^2$.

5 data tables

Upper limit on the WIMP-nucleon scattering cross section from the multiple-scatter analysis.

Upper limit on the WIMP-nucleus scattering cross section from the multiple-scatter analysis.

Upper limit on the WIMP-nucleon scattering cross section from the single-scatter analysis.

More…

First Constraints on WIMP-Nucleon Effective Field Theory Couplings in an Extended Energy Region From LUX-ZEPLIN

The LZ collaboration Aalbers, J. ; Akerib, D.S. ; Musalhi, A.K. Al ; et al.
Phys.Rev.D 109 (2024) 092003, 2024.
Inspire Record 2729878 DOI 10.17182/hepdata.145873

Following the first science results of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time projection chamber operating from the Sanford Underground Research Facility in Lead, South Dakota, USA, we report the initial limits on a model-independent non-relativistic effective field theory describing the complete set of possible interactions of a weakly interacting massive particle (WIMP) with a nucleon. These results utilize the same 5.5 t fiducial mass and 60 live days of exposure collected for the LZ spin-independent and spin-dependent analyses while extending the upper limit of the energy region of interest by a factor of 7.5 to 270 keVnr. No significant excess in this high energy region is observed. Using a profile-likelihood ratio analysis, we report 90% confidence level exclusion limits on the coupling of each individual non-relativistic WIMP-nucleon operator for both elastic and inelastic interactions in the isoscalar and isovector bases.

58 data tables

Data points used in analysis in log_10(S2)-S1 space.

Data selection efficiency as a function of nuclear recoil energy

Isoscalar WIMP-nucleon elastic coupling limit for Operator 8

More…

A search for new physics in low-energy electron recoils from the first LZ exposure

The LZ collaboration Aalbers, J. ; Akerib, D.S. ; Musalhi, A.K. Al ; et al.
Phys.Rev.D 108 (2023) 072006, 2023.
Inspire Record 2683605 DOI 10.17182/hepdata.144761

The LUX-ZEPLIN (LZ) experiment is a dark matter detector centered on a dual-phase xenon time projection chamber. We report searches for new physics appearing through few-keV-scale electron recoils, using the experiment's first exposure of 60 live days and a fiducial mass of 5.5t. The data are found to be consistent with a background-only hypothesis, and limits are set on models for new physics including solar axion electron coupling, solar neutrino magnetic moment and millicharge, and electron couplings to galactic axion-like particles and hidden photons. Similar limits are set on weakly interacting massive particle (WIMP) dark matter producing signals through ionized atomic states from the Migdal effect.

10 data tables

The SR1 data in the {S1c, log10S2c} space with respect to observed time. Top plot is first half of SR1 containing 178 of the final data set. Bottom plot is second half of SR1 containing 157 events.

Electronic Recoil (ER) detection efficiency evaluated as a function of simulated true ER energy [keVee]. The data contains ER detection efficiency for ROI of study.

The observed 90% C.L upper limit on effective neutrino magnetic moment (\mu_{\nu}[\mu_{B}]) in SR1. The data contains observed upper limit, median sensitivity and 1\sigma and 2\sigma sensitivity range.

More…

First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment

The LZ collaboration Aalbers, J. ; Akerib, D.S. ; Akerlof, C.W. ; et al.
Phys.Rev.Lett. 131 (2023) 041002, 2023.
Inspire Record 2107834 DOI 10.17182/hepdata.144760

The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c$^2$. The most stringent limit is set for spin-independent scattering at 36 GeV/c$^2$, rejecting cross sections above 9.2$\times 10^{-48}$ cm$^2$ at the 90% confidence level.

5 data tables

90% CL WIMP SI cross sections, including sensitivities

90% CL WIMP SDn cross sections, including sensitivities and nuclear structure uncertainties

90% CL WIMP SDp cross sections, including sensitivities and nuclear structure uncertainties

More…

A low-mass dark matter search using ionization signals in XENON100

The XENON collaboration Aprile, E. ; Aalbers, J. ; Agostini, F. ; et al.
Phys.Rev.D 94 (2016) 092001, 2016.
Inspire Record 1463250 DOI 10.17182/hepdata.78548

We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7\,keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be constructed without a primary scintillation signal. Instead, we compute an upper limit on the WIMP-nucleon scattering cross section under the assumption that every event passing our selection criteria could be a signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs with a mass of 6\,GeV/$c^2$ above $1.4 \times 10^{-41}$\,cm$^2$ at 90\% confidence level.

1 data table

WIMP exclusion limit on the spin-independent WIMP-nucleon scattering cross section at 90% confidence level.


BICEP2 I: Detection Of B-mode Polarization at Degree Angular Scales

The BICEP2 collaboration Ade, P.A.R. ; Aikin, R.W. ; Barkats, D. ; et al.
Phys.Rev.Lett. 112 (2014) 241101, 2014.
Inspire Record 1286113 DOI 10.17182/hepdata.62706

(abridged for arXiv) We report results from the BICEP2 experiment, a cosmic microwave background (CMB) polarimeter specifically designed to search for the signal of inflationary gravitational waves in the B-mode power spectrum around $\ell\sim80$. The telescope comprised a 26 cm aperture all-cold refracting optical system equipped with a focal plane of 512 antenna coupled transition edge sensor 150 GHz bolometers each with temperature sensitivity of $\approx300\mu\mathrm{K}_\mathrm{CMB}\sqrt{s}$. BICEP2 observed from the South Pole for three seasons from 2010 to 2012. A low-foreground region of sky with an effective area of 380 square deg was observed to a depth of 87 nK deg in Stokes $Q$ and $U$. We find an excess of $B$-mode power over the base lensed-LCDM expectation in the range $30< \ell< 150$, inconsistent with the null hypothesis at a significance of $> 5\sigma$. Through jackknife tests and simulations we show that systematic contamination is much smaller than the observed excess. We also examine a number of available models of polarized dust emission and find that at their default parameter values they predict power $\sim(5-10)\times$ smaller than the observed excess signal. However, these models are not sufficiently constrained to exclude the possibility of dust emission bright enough to explain the entire excess signal. Cross correlating BICEP2 against 100 GHz maps from the BICEP1 experiment, the excess signal is confirmed and its spectral index is found to be consistent with that of the CMB, disfavoring dust at $1.7\sigma$. The observed $B$-mode power spectrum is well fit by a lensed-LCDM + tensor theoretical model with tensor-to-scalar ratio $r=0.20^{+0.07}_{-0.05}$, with $r=0$ disfavored at $7.0\sigma$. Accounting for the contribution of foreground dust will shift this value downward by an amount which will be better constrained with upcoming data sets.

2 data tables

BICEP2 TT, TE, EE, BB, TB, and EB bandpowers, ell*(ell+1)*C(ell)/(2*PI), and uncertainties, corresponding to Figure 2. Uncertainties are statistical only, the standard deviation of the constrained lensed-LambdaCDM+noise simulations, and are calculated as the square root of diagonal elements of the bandpower covariance matrix. The nature of the simulations constrains T to match the observed sky, thus TT, TE, and TB uncertainties do not include appropriate sample variance, and sample variance for a tensor BB signal is not included either. The calibration procedure uses TB and EB to constrain the polarization angle, thus TB and EB cannot be used to measure astrophysical polarization rotation.

Likelihood for the tensor-to-scalar ratio, r, derived from the BICEP2 BB spectrum, corresponding to the black curve from the middle panel of Figure 10, and calculated via the "direct likelihood" method described in Section 11.1.