Showing 10 of 18 results
Elliptic flow (v_2) values for identified particles at midrapidity in Au + Au collisions measured by the STAR experiment in the Beam Energy Scan at the Relativistic Heavy Ion Collider at sqrt{s_{NN}}= 7.7--62.4 GeV are presented for three centrality classes. The centrality dependence and the data at sqrt{s_{NN}}= 14.5 GeV are new. Except at the lowest beam energies we observe a similar relative v_2 baryon-meson splitting for all centrality classes which is in agreement within 15% with the number-of-constituent quark scaling. The larger v_2 for most particles relative to antiparticles, already observed for minimum bias collisions, shows a clear centrality dependence, with the largest difference for the most central collisions. Also, the results are compared with A Multiphase Transport Model and fit with a Blast Wave model.
No description provided.
The difference in $v_{2}$ between particles (X) and their corresponding antiparticles $\bar{X}$ (see legend) as a function of $\sqrt{s_{NN}}$ for 10%-40% central Au + Au collisions. The systematic errors are shown by the hooked error bars. The dashed lines in the plot are fits with a power-law function.
No description provided.
The difference in $v_{2}$ between protons and antiprotons as a function of $\sqrt{s_{NN}}$ for 0%-10%, 10%-40% and 40%-80% central Au + Au collisions. The systematic errors are shown by the hooked error bars. The dashed lines in the plot are fits with a power-law function.
No description provided.
The relative difference. The systematic errors are shown by the hooked error bars. The dashed lines in the plot are fits with a power-law function.
No description provided.
The $v_{2}$ difference between protons and antiprotons (and between $\pi^{+}$ and $pi^{-}$) for 10%-40% centrality Au+Au collisions at 7.7, 11.5, 14.5, and 19.6 GeV. The $v_{2}{BBC} results were slightly shifted horizontally.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
We report the first results of elliptic ($v_2$), triangular ($v_3$) and quadrangular flow ($v_4$) of charged particles in Pb-Pb collisions at $\sqrt{s_{\rm NN}}=5.02$ TeV with the ALICE detector at the CERN Large Hadron Collider. The measurements are performed in the central pseudorapidity region $|\eta|<0.8$ and for the transverse momentum range $0.2<p_{\rm T}<5$ GeV/$c$. The anisotropic flow is measured using two-particle correlations with a pseudorapidity gap greater than one unit and with the multi-particle cumulant method. Compared to results from Pb-Pb collisions at $\sqrt{s_{\rm NN}}=2.76$ TeV, the anisotropic flow coefficients $v_{2}$, $v_{3}$ and $v_{4}$ are found to increase by ($3.0\pm0.6$)%, ($4.3\pm1.4$)% and ($10.2\pm3.8$)%, respectively, in the centrality range 0-50%. This increase can be attributed mostly to an increase of the average transverse momentum between the two energies. The measurements are found to be compatible with hydrodynamic model calculations. This comparison provides a unique opportunity to test the validity of the hydrodynamic picture and the power to further discriminate between various possibilities for the temperature dependence of shear viscosity to entropy density ratio of the produced matter in heavy-ion collisions at the highest energies.
Centrality dependence of $v_2$, with two- and multi-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/$c$, at $\sqrt{s_{\rm NN}}$ = 5.02 TeV.
Centrality dependence of $v_2$, with two- and multi-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/$c$, at $\sqrt{s_{\rm NN}}$ = 5.02 TeV.
Centrality dependence of $v_3$ and $v_4$, with two-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/c, at $\sqrt{s_{\rm NN}}$ = 5.02 TeV.
Centrality dependence of $v_3$ and $v_4$, with two-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/c, at $\sqrt{s_{\rm NN}}$ = 5.02 TeV.
Centrality dependence of $v_2$, with two- and multi-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/c, at $\sqrt{s_{\rm NN}}$ = 2.76 TeV.
Centrality dependence of $v_2$, with two- and multi-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/c, at $\sqrt{s_{\rm NN}}$ = 2.76 TeV.
Centrality dependence of $v_3$ and $v_4$, with two-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/c, at $\sqrt{s_{\rm NN}}$ = 2.76 TeV.
Centrality dependence of $v_3$ and $v_4$, with two-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/c, at $\sqrt{s_{\rm NN}}$ = 2.76 TeV.
Ratio of $p_{\rm T}$-integrated $v_2$ between $\sqrt{s_{\rm NN}}$ = 5.02 and 2.76 TeV.
Ratio of $p_{\rm T}$-integrated $v_2$ between $\sqrt{s_{\rm NN}}$ = 5.02 and 2.76 TeV.
Ratio of $p_{\rm T}$-integrated $v_3$ and $v_4$ between $\sqrt{s_{\rm NN}}$ = 5.02 and 2.76 TeV.
Ratio of $p_{\rm T}$-integrated $v_3$ and $v_4$ between $\sqrt{s_{\rm NN}}$ = 5.02 and 2.76 TeV.
$p_{\rm T}$ dependence of $v_2$, $v_3$ and $v_4$ for centrality 0-5%.
$p_{\rm T}$ dependence of $v_2$, $v_3$ and $v_4$ for centrality 0-5%.
$p_{\rm T}$ dependence of $v_2$, $v_3$ and $v_4$ for centrality 30-40%.
$p_{\rm T}$ dependence of $v_2$, $v_3$ and $v_4$ for centrality 30-40%.
$p_{\rm T}$ dependence of $v_2${4} for centralities 10-20%, 20-30% and 30-40%.
$p_{\rm T}$ dependence of $v_2${4} for centralities 10-20%, 20-30% and 30-40%.
Ratio of $p_{\rm T}$-differential $v_2${4} between $\sqrt{s_{\rm NN}}$ = 5.02 and 2.76 TeV, for centrality 20-30%.
Ratio of $p_{\rm T}$-differential $v_2${4} between $\sqrt{s_{\rm NN}}$ = 5.02 and 2.76 TeV, for centrality 20-30%.
Fully $p_{\rm T}$-integrated $v_2${4} at $\sqrt{s_{\rm NN}}$ = 2.76 and 5.02 TeV, for centrality 20-30%.
Fully $p_{\rm T}$-integrated $v_2${4} at $\sqrt{s_{\rm NN}}$ = 2.76 and 5.02 TeV, for centrality 20-30%.
This paper describes the measurement of elliptic flow of charged particles in lead-lead collisions at sqrt(s_NN) = 2.76 TeV using the ATLAS detector at the Large Hadron Collider (LHC). The results are based on an integrated luminosity of approximately 7 ub^-1. Elliptic flow is measured over a wide region in pseudorapidity, |eta| < 2.5, and over a broad range in transverse momentum, 0.5 < p_T < 20 GeV. The elliptic flow parameter v_2 is obtained by correlating individual tracks with the event plane measured using energy deposited in the forward calorimeters. As a function of transverse momentum, v_2(p_T) reaches a maximum at p_T of about 3 GeV, then decreases and becomes weakly dependent on p_T above 7 - 8 GeV. Over the measured pseudorapidity region, v_2 is found to be approximately independent of |eta| for all collision centralities and particle transverse momenta, something not observed in lower energy collisions. The results are discussed in the context of previous measurements at lower collision energies, as well as recent results from the LHC.
v2(pT) for centrality interval 0-10% and |eta| <1.
v2(pT) for centrality interval 10-20% and |eta| <1.
v2(pT) for centrality interval 20-30% and |eta| <1.
v2(pT) for centrality interval 30-40% and |eta| <1.
v2(pT) for centrality interval 40-50% and |eta| <1.
v2(pT) for centrality interval 50-60% and |eta| <1.
v2(pT) for centrality interval 60-70% and |eta| <1.
v2(pT) for centrality interval 70-80% and |eta| <1.
v2(pT) for centrality interval 0-10% and 1< |eta| <2.
v2(pT) for centrality interval 10-20% and 1< |eta| <2.
v2(pT) for centrality interval 20-30% and 1< |eta| <2.
v2(pT) for centrality interval 30-40% and 1< |eta| <2.
v2(pT) for centrality interval 40-50% and 1< |eta| <2.
v2(pT) for centrality interval 50-60% and 1< |eta| <2.
v2(pT) for centrality interval 60-70% and 1< |eta| <2.
v2(pT) for centrality interval 70-80% and 1< |eta| <2.
v2(pT) for centrality interval 0-10% and 2< |eta| <2.5.
v2(pT) for centrality interval 10-20% and 2< |eta| <2.5.
v2(pT) for centrality interval 20-30% and 2< |eta| <2.5.
v2(pT) for centrality interval 30-40% and 2< |eta| <2.5.
v2(pT) for centrality interval 40-50% and 2< |eta| <2.5.
v2(pT) for centrality interval 50-60% and 2< |eta| <2.5.
v2(pT) for centrality interval 60-70% and 2< |eta| <2.5.
v2(pT) for centrality interval 70-80% and 2< |eta| <2.5.
v2(eta) for centrality interval 0-10% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 10-20% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 20-30% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 30-40% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 40-50% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 50-60% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 60-70% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 70-80% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 0-10% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 10-20% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 20-30% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 30-40% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 40-50% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 50-60% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 60-70% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 70-80% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 0-10% and 2< pT <4 GeV.
v2(eta) for centrality interval 10-20% and 2< pT <4 GeV.
v2(eta) for centrality interval 20-30% and 2< pT <4 GeV.
v2(eta) for centrality interval 30-40% and 2< pT <4 GeV.
v2(eta) for centrality interval 40-50% and 2< pT <4 GeV.
v2(eta) for centrality interval 50-60% and 2< pT <4 GeV.
v2(eta) for centrality interval 60-70% and 2< pT <4 GeV.
v2(eta) for centrality interval 70-80% and 2< pT <4 GeV.
v2(eta) for centrality interval 0-10% and 4< pT <7 GeV.
v2(eta) for centrality interval 10-20% and 4< pT <7 GeV.
v2(eta) for centrality interval 20-30% and 4< pT <7 GeV.
v2(eta) for centrality interval 30-40% and 4< pT <7 GeV.
v2(eta) for centrality interval 40-50% and 4< pT <7 GeV.
v2(eta) for centrality interval 50-60% and 4< pT <7 GeV.
v2(eta) for centrality interval 60-70% and 4< pT <7 GeV.
v2(eta) for centrality interval 70-80% and 4< pT <7 GeV.
v2(eta) for centrality interval 0-10% and 9< pT <20 GeV.
v2(eta) for centrality interval 10-20% and 9< pT <20 GeV.
v2(eta) for centrality interval 20-30% and 9< pT <20 GeV.
v2(eta) for centrality interval 30-40% and 9< pT <20 GeV.
v2(eta) for centrality interval 40-50% and 9< pT <20 GeV.
v2(eta) for centrality interval 50-60% and 9< pT <20 GeV.
v2(eta) for centrality interval 60-70% and 9< pT <20 GeV.
v2(eta) for centrality interval 70-80% and 9< pT <20 GeV.
Dihadron angular correlations in $d$+Au collisions at $\sqrt{s_{\rm NN}}=200$ GeV are reported as a function of the measured zero-degree calorimeter neutral energy and the forward charged hadron multiplicity in the Au-beam direction. A finite correlated yield is observed at large relative pseudorapidity ($\Delta\eta$) on the near side (i.e. relative azimuth $\Delta\phi\sim0$). This correlated yield as a function of $\Delta\eta$ appears to scale with the dominant, primarily jet-related, away-side ($\Delta\phi\sim\pi$) yield. The Fourier coefficients of the $\Delta\phi$ correlation, $V_{n}=\langle\cos n\Delta\phi\rangle$, have a strong $\Delta\eta$ dependence. In addition, it is found that $V_{1}$ is approximately inversely proportional to the mid-rapidity event multiplicity, while $V_{2}$ is independent of it with similar magnitude in the forward ($d$-going) and backward (Au-going) directions.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for 1.2 < $|\Delta\eta|$ < 1.8 in d+Au collisions, for low ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for 1.2 < $|\Delta\eta|$ < 1.8 in d+Au collisions, for high ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for -4.5 < $\Delta\eta$ < -2 in d+Au collisions, for low ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for -4.5 < $\Delta\eta$ < -2 in d+Au collisions, for high ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for 2 < $\Delta\eta$ < 4.5 in d+Au collisions, for low ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for 2 < $\Delta\eta$ < 4.5 in d+Au collisions, for high ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
The $\Delta\eta$ dependence of the near-side (|$\Delta\phi$| < $\pi/3$) correlated yield. Positive(negative) $\eta$ corresponds to d(Au)-going direction. Only high ZDC-Au activity data are shown.
The $\Delta\eta$ dependence of the away-side (|$\Delta\phi - \pi$| < $\pi/3$) correlated yield. Positive(negative) $\eta$ corresponds to d(Au)-going direction. Only high ZDC-Au activity data are shown.
The $\Delta\eta$ dependence of the ratio of the near- to away-side correlated yields in d+Au collisions. Positive(negative) $\eta$ corresponds to d(Au)-going direction. Only high ZDC-Au activity data are shown.
The $\Delta\eta$ dependence of the second harmonic Fourier coefficient, V2, in low ZDC-Au activity d+Au collisions.
The $\Delta\eta$ dependence of the second harmonic Fourier coefficient, V2, in high ZDC-Au activity d+Au collisions.
Fourier coefficient V1 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by FTPC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be 10% on V1. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V1 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC. Trigger particles are from TPC, and associated particles from FTPC-Au. Systematic uncertainties are estimated to be 10% on V1. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V1 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC. Trigger particles are from TPC, and associated particles from FTPC-d. Systematic uncertainties are estimated to be 10% on V1. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V1 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be 10% on V1. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V2 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by FTPC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be 10% on V2. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V2 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from FTPC-Au. Systematic uncertainties are estimated to be 10% on V2. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V2 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from FTPC-d. Systematic uncertainties are estimated to be 10% on V2. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V2 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be 10% on V2. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V3 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selections is by FTPC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be smaller than statistical errors for V3. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V3 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from FTPC-Au. Systematic uncertainties are estimated to be smaller than statistical errors for V3. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V3 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from FTPC-d. Systematic uncertainties are estimated to be smaller than statistical errors for V3. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V3 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be smaller than statistical errors for V3. Errors shown are the quadratic sum of statistical and systematic errors.
We present measurements of $\pi^-$ and $\pi^+$ elliptic flow, $v_2$, at midrapidity in Au+Au collisions at $\sqrt{s_{_{\rm NN}}} =$ 200, 62.4, 39, 27, 19.6, 11.5 and 7.7 GeV, as a function of event-by-event charge asymmetry, $A_{ch}$, based on data from the STAR experiment at RHIC. We find that $\pi^-$ ($\pi^+$) elliptic flow linearly increases (decreases) with charge asymmetry for most centrality bins at $\sqrt{s_{_{\rm NN}}} = \text{27 GeV}$ and higher. At $\sqrt{s_{_{\rm NN}}} = \text{200 GeV}$, the slope of the difference of $v_2$ between $\pi^-$ and $\pi^+$ as a function of $A_{ch}$ exhibits a centrality dependence, which is qualitatively similar to calculations that incorporate a chiral magnetic wave effect. Similar centrality dependence is also observed at lower energies.
The distribution of observed charge asymmetry from STAR data.
Pion $v_2${2} as a function of observed charge asymmetry.
$v_2$ difference between $\pi^-$ and $\pi^+$ as a function of charge asymmetry with the tracking efficiency correction, for 30-40% central Au+Au collisions at 200 GeV. The errors are statistical only.
The slope parameter r as a function of centrality for collision energy of 200 GeV.
The slope parameter r as a function of centrality for collision energy of 62.4 GeV.
The slope parameter r as a function of centrality for collision energy of 39 GeV.
The slope parameter r as a function of centrality for collision energy of 27 GeV.
The slope parameter r as a function of centrality for collision energy of 19.6 GeV.
The slope parameter r as a function of centrality for collision energy of 11.5 GeV.
The slope parameter r as a function of centrality for collision energy of 7.7 GeV.
Collisions between prolate uranium nuclei are used to study how particle production and azimuthal anisotropies depend on initial geometry in heavy-ion collisions. We report the two- and four-particle cumulants, $v_2\{2\}$ and $v_2\{4\}$, for charged hadrons from U+U collisions at $\sqrt{s_{\rm NN}}$ = 193 GeV and Au+Au collisions at $\sqrt{s_{\rm NN}}$ = 200 GeV. Nearly fully overlapping collisions are selected based on the amount of energy deposited by spectators in the STAR Zero Degree Calorimeters (ZDCs). Within this sample, the observed dependence of $v_2\{2\}$ on multiplicity demonstrates that ZDC information combined with multiplicity can preferentially select different overlap configurations in U+U collisions. An initial-state model with gluon saturation describes the slope of $v_2\{2\}$ as a function of multiplicity in central collisions better than one based on Glauber with a two-component multiplicity model.
We present high precision measurements of elliptic flow near midrapidity ($|y|<1.0$) for multi-strange hadrons and $\phi$ meson as a function of centrality and transverse momentum in Au+Au collisions at center of mass energy $\sqrt{s_{NN}}=$ 200 GeV. We observe that the transverse momentum dependence of $\phi$ and $\Omega$ $v_{2}$ is similar to that of $\pi$ and $p$, respectively, which may indicate that the heavier strange quark flows as strongly as the lighter up and down quarks. This observation constitutes a clear piece of evidence for the development of partonic collectivity in heavy-ion collisions at the top RHIC energy. Number of constituent quark scaling is found to hold within statistical uncertainty for both 0-30$\%$ and 30-80$\%$ collision centrality. There is an indication of the breakdown of previously observed mass ordering between $\phi$ and proton $v_{2}$ at low transverse momentum in the 0-30$\%$ centrality range, possibly indicating late hadronic interactions affecting the proton $v_{2}$.
ATLAS measurements of the azimuthal anisotropy in lead-lead collisions at $\sqrt{s_{NN}}=2.76$ TeV are shown using a dataset of approximately 7 $\mu$b$^{-1}$ collected at the LHC in 2010. The measurements are performed for charged particles with transverse momenta $0.5<p_T<20$ GeV and in the pseudorapidity range $|\eta|<2.5$. The anisotropy is characterized by the Fourier coefficients, $v_n$, of the charged-particle azimuthal angle distribution for n = 2-4. The Fourier coefficients are evaluated using multi-particle cumulants calculated with the generating function method. Results on the transverse momentum, pseudorapidity and centrality dependence of the $v_n$ coefficients are presented. The elliptic flow, $v_2$, is obtained from the two-, four-, six- and eight-particle cumulants while higher-order coefficients, $v_3$ and $v_4$, are determined with two- and four-particle cumulants. Flow harmonics $v_n$ measured with four-particle cumulants are significantly reduced compared to the measurement involving two-particle cumulants. A comparison to $v_n$ measurements obtained using different analysis methods and previously reported by the LHC experiments is also shown. Results of measurements of flow fluctuations evaluated with multi-particle cumulants are shown as a function of transverse momentum and the collision centrality. Models of the initial spatial geometry and its fluctuations fail to describe the flow fluctuations measurements.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 0-2%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-2%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 40-50%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 10-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 20-30%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 30-40%.
The triangular flow harmonic measured with the two-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The triangular flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-25%.
The triangular flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The triangular flow harmonic measured with the two-particle cumulats as a function of transverse momentum in centrality bin 25-60%.
The triangular flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 25-60%.
The triangular flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 25-60%.
The quadrangular flow harmonic measured with the two-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The quadrangular flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-25%.
The quadrangular flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 0-2%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 0-2%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 60-80%.
The triangular flow harmonic measured with the two-particle cumulats as a function of pseudorapidity in centrality bin 0-60%.
The triangular flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 0-60%.
The triangular flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 0-60%.
The quadrangular flow harmonic measured with the two-particle cumulats as a function of pseudorapidity in centrality bin 0-25%.
The quadrangular flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 0-25%.
The quadrangular flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 0-25%.
The second flow harmonic measured with the two-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the four-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the six-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the eight-particle cumulats as a function of <Npart>.
The ratio of second flow harmonics measured with the six- and four-particle cumulants as a function of <Npart>.
The ratio of second flow harmonics measured with the eight- and four-particle cumulants as a function of <Npart>.
The second flow harmonic measured with the Event Plane method as a function of <Npart>.
The triangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The quadrangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctuations, F(v2), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v3), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v4), as a function of <Npart>.
The second flow harmonic measured with the two-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the four-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the six-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the eight-particle cumulats as a function of <Npart>.
The ratio of second flow harmonics measured with the six- and four-particle cumulants as a function of <Npart>.
The ratio of second flow harmonics measured with the eight- and four-particle cumulants as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctuations, F(v2), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v3), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v4), as a function of <Npart>.
Two-particle angular correlations between trigger particles in the forward pseudorapidity range ($2.5 < |\eta| < 4.0$) and associated particles in the central range ($|\eta| < 1.0$) are measured with the ALICE detector in p-Pb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV. The trigger particles are reconstructed using the muon spectrometer, and the associated particles by the central barrel tracking detectors. In high-multiplicity events, the double-ridge structure, previously discovered in two-particle angular correlations at midrapidity, is found to persist to the pseudorapidity ranges studied in this Letter. The second-order Fourier coefficients for muons in high-multiplicity events are extracted after jet-like correlations from low-multiplicity events have been subtracted. The coefficients are found to have a similar transverse momentum ($p_{\rm T}$) dependence in p-going (p-Pb) and Pb-going (Pb-p) configurations, with the Pb-going coefficients larger by about $16\pm6$%, rather independent of $p_{\rm T}$ within the uncertainties of the measurement. The data are compared with calculations using the AMPT model, which predicts a different $p_{\rm T}$ and $\eta$ dependence than observed in the data. The results are sensitive to the parent particle $v_2$ and composition of reconstructed muon tracks, where the contribution from heavy flavour decays are expected to dominate at $p_{\rm T}>2$ GeV/$c$.
$v_{2}^{\mu}\{\rm{2PC,sub}\}$ extracted from muon-track correlations.
$v_{2}^{\mu}\{\rm{2PC,sub}\}$ coefficients from muon-tracklet correlations in p-going direction.
$v_{2}^{\mu}\{\rm{2PC,sub}\}$ coefficients from muon-tracklet correlations in Pb-going direction.
Fig. 5: Ratio between the $v_{2}^{\mu}\{\rm{2PC,sub}\}$ coefficients from muon-tracklet correlations in Pb-going direction and in the p-going direction.
We present measurements of the azimuthal dependence of charged jet production in central and semi-central $\sqrt{s_{\mathrm{NN}}}$ = 2.76 TeV Pb-Pb collisions with respect to the second harmonic event plane, quantified as $v_{2}^{\mathrm{ch~jet}}$. Jet finding is performed employing the anti-$k_{\mathrm{T}}$ algorithm with a resolution parameter $R$ = 0.2 using charged tracks from the ALICE tracking system. The contribution of the azimuthal anisotropy of the underlying event is taken into account event-by-event. The remaining (statistical) region-to-region fluctuations are removed on an ensemble basis by unfolding the jet spectra for different event plane orientations independently. Significant non-zero $v_{2}^{\mathrm{ch~jet}}$ is observed in semi-central collisions (30-50\% centrality) for 20 $<$ $p_{\mathrm{T}}^{\rm ch~jet}$ $<$ 90 ${\mathrm{GeV}\kern-0.05em/\kern-0.02em c}$. The azimuthal dependence of the charged jet production is similar to the dependence observed for jets comprising both charged and neutral fragments, and compatible with measurements of the $v_2$ of single charged particles at high $p_{\mathrm{T}}$. Good agreement between the data and predictions from JEWEL, an event generator simulating parton shower evolution in the presence of a dense QCD medium, is found in semi-central collisions.
Second-order harmonic coefficient $v_2^{ch~jet}$ as function a of $p_{T}^{ch~jet}$ for 0--5% collision centrality.
Second-order harmonic coefficient $v_2^{ch~jet}$ as function a of $p_{T}^{ch~jet}$ for 30--50% collision centrality.
When you search on a word, e.g. 'collisions', we will automatically search across everything we store about a record. But, sometimes you may wish to be more specific. Here we show you how.
Guidance and examples on the query string syntax can be found in the Elasticsearch documentation.
About HEPData Submitting to HEPData HEPData File Formats HEPData Coordinators HEPData Terms of Use HEPData Cookie Policy
Status Email Forum Twitter GitHub
Copyright ~1975-Present, HEPData | Powered by Invenio, funded by STFC, hosted and originally developed at CERN, supported and further developed at IPPP Durham.